PressureTransducer 25 Pa/ ES 961 – Discontinued

Item no.: 40744

View dealers
Support If you have questions or need assistance in choosing amongst or using our products, please do not hesitate to contact customer service:

Product is discontinued.
No direct substitution for this pressure area. However, in most casses PressureBox ED 50 / ES 1088 (item number 4075) can be used.

PressureTransducer 0-25Pa with 0-10V DC output signal based on micro-flow measurement.

The pressure transducer is equipped with a half/full scale selector. Use the jumper to switch between half scale and full scale. In half scale mode, the output voltage is 10 volt at 50% of the sensors maximum. Example: In half scale mode the pressure transducer has an output of 0V at 0Pa and 10V at 12,5 Pa. If the unit in half scale mode is exposed to a pressure outside the max range, the output voltage may increase to 12V.

NB! The pressure transducer is only to be used in a non condensing environment and in non aggressive air.

EAN Number

5703471407440

Size (HxWxD)

80x80x55 mm

Enclosure

IP 54

Supply Voltage

24 VAC

Alternate Supply

15 – 30 VDC

Ambient Operating Temperature

-20 – 60 °C

Måleområde 1

0-25 Pa

Measurement Area 2

0 – 12.5 Pa

Number of 0-10V Outputs

1

0-10V Output Current

10 mA